ASTM B 117 |
|
|
ASTM B 117 : Standard Practice for Operating Salt Spray (Fog) Apparatus
This practice describes the apparatus, procedure, and conditions
required to create and maintain the salt spray (fog) test environment.
Suitable apparatus wich may be used is described in Appendix X1. This
practice does not prescribe the type of test specimen or exposure
periods to be used for a specific product, nor the interpretation to be
given to the results.
The values stated in SI units are to be regarded as standard. The
inch-pound units in parentheses are provided for information and may be
approximate.
Use a 5% salt solution at 92-97 degrees F in a sealed weather cabinet.
Scribe X in steel zinc phosphated test panel to bare metal. Inspect
every 24 hours. End test and total hours after 1/4" creepage from
scribed area. Creepage shall not exceed 1/4" in either direction from
scribe line after 500 hours exposure.
|
|
|
|