ASTM D 1525 |
|
ASTM D 1525 : Standard Test Method for Vicat Softening Temperature of
Plastics
This test method
covers determination of the temperature at wich a specified needle
penetration occurs when specimens are subjected to specified controlled
test conditions.
This test method is not recommended for ethyl cellulose, nonrigid poly
(vinyl chloride), poly (vinylidene chloride), or other materials having
a wide Vicat softening range.
The values stated in SI units are to be regarded as the standard.
Note 1 : This test method ans ISO 306 are technically equivalent, with
the exception of the allowance for creep, prior to beginning the test,
in this test method.
|
|
|
|